Chamberlain ELITE EL25 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Interphones de porte Chamberlain ELITE EL25. Chamberlain ELITE EL25 User's Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 26
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Quickstart
EL25
Keypad Programming Guide
EL25
Keypad Programming Guide
Telephone entry/access control system with a 25 directory code capacity
®
© 2005 The Chamberlain Group, Inc.
All Rights Reserved
Quickstart
This Quickstart Guide is intended to highlight some applications. These instructions are not intended to be
comprehensive. Please consult the Keypad Programming Manual for complete information.
Vue de la page 0
1 2 3 4 5 6 ... 25 26

Résumé du contenu

Page 1 - Quickstart

QuickstartEL25 Keypad Programming GuideEL25 Keypad Programming GuideTelephone entry/access control system with a 25 directory code capacity®™© 2005 Th

Page 2 - Important:

Page 9Programming Multiple Units OverviewNote: You cannot program a unit within a multi-unit chain from a local/remote DTMF phone (Touch-Tone) unless

Page 3

Page 10Getting StartedEL25 SetUp “Your Settings”Change the unit password to prevent any tampering with your system's database. When changing the

Page 4

Page 11A relay is a device that reacts to an electric current to activate other devices. Allowing the EL25 to lock or unlock a door/gate, shunt (bypas

Page 5 - Order of relays is 4321

Page 12To perform these 4 steps you MUST know EXACTLY where the External Access Control Device(s) were wired in “Your” EL25! When the table on page 14

Page 6

Page 131 Press2 Enter the Relay Number (1-4). Then (#)3 Enter Activation Time (1-300 Seconds). Then (#)Then1 Press2 Enter Door Number (1-4). Then

Page 7 - Changing the Password”

Page 14Sample: EL25 Controlling 1 Door (Page 16)EL25 SetUp “Your Settings”EL25 SetUp “Your Settings”When “Your Door Settings” or “Door 1,2,3 or 4” are

Page 8 - Exit Programming Mode

Page 15How your system has been wired is an important part of programming it. Write down your configuration. To help visualize it, draw a map of it be

Page 9

Page 16EL25 SetUp “Your Settings”EL25 SetUp “Your Settings”Relay 1 - Strike Mode Unlocks Door for 10 sec.Relay 2 - Control Mode Turns on Security Ligh

Page 10 - Verify Unit Number:

Page 17EL25 SetUp “Your Settings”EL25 SetUp “Your Settings”EL25Main Keypad (Front Door)Wiegand Keypad (Exit)Card Reader(Back Door)Card Reader(Manager&

Page 11 - EL25 SetUp “Your Settings”

Page 18Location Door No. Relay Relay Mode Relay Function Relay Activation Time (Seconds)DrivewayPedestrian GateIn EL251 Strike Opens Vehicular Gate 10

Page 12

Page 1ProgrammingNumberFactorySettingDescription of Task Programming Procedure***12 # Enable/Disable True Anti-Passback (0 = disable;1 = enable) # Ena

Page 13

Page 19Location Relay Relay Mode Relay Function Relay Activation Time (Seconds)Front Door (Entrance)Vehicular GatePool GateFront Door (Entrance)1 Stri

Page 14

Page 20Entry CodesAccess Cards1 Press2 Enter Entry Code (3-9 digits). Then (#)Factory Setting for Entry Code Length is 4 digitsSee “Entry Code Lengt

Page 15 - “Your” Door Settings

Page 21Transmitters1 Press2 Enter Transmitter Number (1-65534). Then (#)Add a Basic transmitter to the system's database. A basic transmitter w

Page 16

Page 22AppendixAppendixQuick Reference GuideGlossaryAppendixGlossaryGlossaryGlossaryGlossaryGlossaryGlossaryAccess Device (RF Receiver, Card Reader, o

Page 17

Page 23AppendixAppendixQuick Reference GuideGlossaryAppendixGate or Door - Used synonymously throughout the manual, these terms refer to controllable

Page 18

Page 24AppendixAppendixAppendixAppendixAccess CardsDirect CommandsEntry CodesProgramming – Enter Program Mode – Exit Program Mode – Multiple Units –

Page 19

© 2005 The Chamberlain Group, Inc.All Rights Reserved114A3042845 Larch AvenueElmhurst, Illinois 60125-1196®™

Page 20

Page 2ProgrammingNumber3030 # (time zone number, 2-63) # (segment number; 99) # (starting time = hhmm; 99) # (ending time = hhmm) # (day of week, 1-8;

Page 21 - Entry Codes / Access Cards

Page 3FactorySettingDescription of Task Programming ProcedureProgrammingNumber61 # (door 1-4) # (relays to activate 0000-1111) # Order of relay is: re

Page 22 - Transmitters

Page 4FactorySettingDescription of Task Programming ProcedureProgrammingNumber86Verify a Card85Replace a Card88Delete a Card90Add a Basic Transmitter9

Page 23 - Appendix

Page 5FactorySettingDescription of Task Programming ProcedureProgrammingNumberVerify Multi-Unit Number111 #105Enable or Disable Anti-PassbackForgivene

Page 24 - Glossary GlossaryGlossary

Page 6Programming BasicsProgramming Single Unit OverviewProgramming Single Unit Overview1 1, 2 or 3 digit Programming Number. (See “Quick Refer

Page 25 - Glossary Glossary

Page 7Enter Programming ModeExit Programming Mode1 Press2 Enter the (6) six-digit password. The default is six zeroes.If you will be programming the

Page 26 - Elmhurst, Illinois 60125-1196

Page 8System Feedback / Responses (Beeps)2 Short Beeps: Programming step was valid.3 Short Beeps: Programming mode was exited.1 Long Beep: Input was

Commentaires sur ces manuels

Pas de commentaire